![]() Observation stands, towers, and platforms and the areas extending not less than 10 feet (3048 mm) horizontally from the outer edge of such structures.Diving structures and the areas extending not less than 10 feet (3048 mm) horizontally from the outer edge of such structures.Pools and the areas extending not less than 10 feet, (3048 mm) horizontally from the inside of the walls of the pool.Įxcept where installed with the clearances specified in Table E4203.6, the following parts of pools and outdoor spas and hot tubs shall not be placed under existing service-drop conductors, overhead service conductor, or any other open overhead wiring nor shall such wiring be installed above the following: For other than underwater and storable pool lighting luminaire, the requirements of Item 1 shall apply to any cord-equipped luminaire that is located within 16 feet (4877 mm) radially from any point on the water surface.A listed packaged spa or hot tub rated at 20 amperes or less and installed indoors shall be permitted to be cord-and-plug-connected to facilitate maintenance and repair.A listed packaged spa or hot tub installed outdoors that is GFCI protected shall be permitted to be cord-and-plug-connected provided that such cord does not exceed 15 feet (4572 mm) in length.Such grounding conductor shall be connected to a grounding terminal in the supply junction box, transformer enclosure, or other enclosure and shall be not smaller than the supply conductors and not smaller than 16 AWG. Other than listed low-voltage lighting systems not requiring grounding, wet-niche luminaires that are supplied by a flexible cord or cable shall have all exposed noncurrent-carrying metal parts grounded by an insulated copper equipment grounding conductor that is an integral part of the cord or cable.Cords that supply swimming pool equipment shall have a copper equipment grounding conductor not smaller than 12 AWG and shall terminate in a grounding-type attachment plug. For other than storable pools, the flexible cord shall not exceed 3 feet (914 mm) in length. For other than underwater luminaires, fixed or stationary equipment shall be permitted to be connected with a flexible cord to facilitate removal or disconnection for maintenance or repair.Indoor spas and hot tubs, and other pool, spa or hot tub associated equipment: from branch circuit OCPD to equipmentĬonnection at pool lighting transformers or power suppliesįlexible cords used in conjunction with a pool, spa, hot tub or hydromassage bathtub shall be installed in accordance with the following: ![]() Packaged or self-contained outdoor spas and hot tubs without underwater luminaire: from branch circuit OCPD to spa or hot tub Packaged or self-contained outdoor spas and hot tubs with underwater luminaire: from branch circuit OCPD to spa or hot tub Pool-associated motors: from branch circuit OCPD to motor h Wet-niche and no-niche luminaires: from deck or junction box to forming shellĭry niche: from branch circuit OCPD to luminaires Wet-niche and no-niche luminaires: from branch circuit OCPD to deck or junction box Panelboard(s) that supply pool equipment: from service equipment to panelboard While we intend to make every attempt to keep the information on this site current, the owners of and contributors to this site make no claims, promises or guarantees about the accuracy, completeness or adequacy of the information contained in or linked to from this site.PERMITTED WIRING METHODS IN CORROSIVE ENVIRONMENTS WIRING LOCATION OR PURPOSE (Application allowed where marked with an "A") Justia cannot guarantee that the information on this website (including any legal information provided by an attorney through this service) is accurate, complete, or up-to-date. Justia assumes no responsibility to any person who relies on information contained on or received through this site and disclaims all liability in respect to such information. You should not act upon information provided in Justia Ask a Lawyer without seeking professional counsel from an attorney admitted or authorized to practice in your jurisdiction. Additionally, no responses on this forum constitute legal advice, which must be tailored to the specific circumstances of each case. ![]() The use of this website to ask questions or receive answers does not create an attorney–client relationship between you and Justia, or between you and any attorney who receives your information or responds to your questions, nor is it intended to create such a relationship. Any information sent through Justia Ask a Lawyer is not secure and is done so on a non-confidential basis only. Justia Ask a Lawyer is a forum for consumers to get answers to basic legal questions.
0 Comments
Leave a Reply. |